2: Configuring and Installing the Device
16 Verint Video Solutions
5. If required, connect the serial port of the S1700e to a PTZ
camera (for instructions, see next).
6. When installing a device with the extended temperature
option, make it stand vertically, allowing for better cooling.
Performing Serial
Connections
The Nextiva edge devices support only the RS-232, RS-422,
and RS-485 asynchronous protocols. For any other protocol,
you may need a converter.
The S1700e device holds connectors for two serial ports:
RS-232 and RS-422/485.
RS-232
Use the following wiring scheme to plug a serial cable to the
DB-9 connector on the front of the device:
DB-9 pin number Cable signal name
2RxD
3TxD
5 Signal ground
7RTS
8CTS